• Hello.
    In order to download file attachments or view image attachments in full size, you must be registered/logged in and have a level 2 member account.
    No worry, its all for free!
    For more details - click here.

Recent content by ricc

  1. R

    5718 power loss

    you say pto is not effected ... is engine running properly and just forward movement is effected? if the transmission clutch is slipping it wont move in high gears but will perhaps creep arround in low gears... perhaps start sluggishly moving after clutch is released and slowly build up speed a...
  2. R

    6911 brake lights operation

    if its the same as a 6711 the brake pedals are connected to two master cylinders , accross the back of the master cylinders theres a balence valve on one end of the valve theres a pressure switch . two spade terminals on it , normally open, closed when theres pressure in the brake lines. fused...
  3. R

    6211 hydraulic pressure

    the rear connectors will do. 2000psi is a ball park figure, how big is the bucket of dirt? some elderly loaders wouldnt lift much over half a ton.
  4. R

    question registering the tractor HELP

    might help to know where in the world you are? in uk you could try dvla or vosa websites?
  5. R

    Zetor 7045 front loader valve block problems

    broken cable would only effect one service not lift and bucket tip together. can you check the supply pressure to the spool valve? , 2500 psi sounds about right, if the releif valve in the spool is dumping all the pressure its not sealing.... worn seat/plunger seal or weak spring. a washer...
  6. R

    8045 no hydraulics or power steering

    steering is a seperate systen to everything else theres a small oil tank on the rhs of the engine , check theres oil in it. the hi lo gears mentioned in the previous post is the torque amplifier lever under the steering wheel ... its a hydraulically actuated epicyclic ... run off the main...
  7. R

    Cab compatibility

    id be surprised if it did,,,the crystals , 80 hp and upwards are totally different animals to the 70hp and smaller tractors.... having said that the brake master cylinders are the same, ive had a 8011 and a 6711 for getting on 30 years and not found much else the same.... except the starter...
  8. R

    Need all information on zetor 3320 serial # 8766

    would be useful to know where you are if youre in the uk id suggest you get a neighbour/friend of your brothers to put them on ebay for you.?
  9. R

    6045

    a good start would be to scroll down about half a dozen threads to the one about cold starting a 6011. go a bit further and youll find more.
  10. R

    proud owner of 4718

    always worth looking on ebay, in the business/agriculture section. theres usually keys on there.
  11. R

    Front end Loader Issue

    as the bucket is working its got to be the slice of the spool valve that controls the arms aint working. is it electric or cable controled.... if its electric probably a duff solenoid or a wire broken,
  12. R

    Zetor 3011 dynamo regulator cut out box

    long time since i played with a dynamo but as far as i can remember 2 and 3 coil ones are interchangeable. should be a thick and a thin wire from regulator to dynamo think the thin will be labled f or m , the thick probably d and may be a larger size connector as well. will be a thick wire...
  13. R

    Difficult cold starting with my 6011

    are you aware of the cold start excess fuel button? pull the hand throttle fully open , then look on the front of the injection pump... the lump on the left side of the engine with diesel pipes on it....on the front of the pump, radiator end, theres a wee metal plunger to push in. push it in...
  14. R

    Zetor 8011;big end and mane bolt torque spec

    hi the manual ive got gives main bearing 180 - 200 nm connecting rod bolts 110-120 nm i guess youll also need head bolts 150-170 nm figures are same for 4 and 6 cylinder engines
  15. R

    Zetor 8011: locked rear wheel in cold temps

    do you park with the handbrake applied? if you do it could be ice or frozen mud jamming the linkage. as the linkages and even the slave cylinders are all visible on the crystal it should be easy to see if thats the problem.
Back
Top